Thermal Analysis of PROX reactor with shell and tube type heat exchanger
Keywords:
-Abstract
The PROX reaction process occurring in the reactor with 1%(wt) platinum based on iron hydroxyphosphate
was analyzed between temperature range of 80 0C and 120 0C in hysys software. A shell and tube type heat exchanger
was designed and analyzed for temperature control for PROX reaction, containing copper tubes. The temperature profile
suggests the expected temperature rise in the PROX reactor and temperature drop in the heat exchanger. The heat
exchanger was able to bring down the temperature of gases from 2100 C to 1130 C successfully. The gas composition
sent to the PROX reaction process was 40% H2, 1% CO, 9% CO2, 0.5% O2, and 49.5% Ar. The result suggests that the
removal of heat from the gases increases the CO selectivity and conversion