PERFORMANCE ANALYSIS OF DROPWISE CONDENSATION

Authors

  • V.Vignesh PG student, Department of Mechanical Engineering, M.R.K Institute of Technology, KattumannarKoil, Tamilnad-608301..
  • C.Vembaiyan Assistant Professor, Department of Mechanical Engineering, M.R.K Institute of Technology, KattumannarKoil, Tamilnadu-608301
  • K.Anandavelu Professor, Department of Mechanical Engineering, M.R.K Institute of Technology, KattumannarKoil, Tamilnadu-608301

Keywords:

Dropwise condensation, Flimwise condensation, vapour deposition, Ni-Cr, Teflon

Abstract

Drop wise condensation (DWC) is under development as it offers extremely high heat transfer (5-7
times higher) by preventing the buildup of the condensate liquid layer formed in the film wise condensation
(FWC). This project work is an experimental based and objective is to break the condensate formed on the
cold surface so as to improve the heat transfer rate. Hence an analysis has been done over circular, elliptical
and rhombus shaped tubes for the performance DWC and rhombus shaped tube is suggested, as its shape will
not permit the buildup of the layer of the condensate.
Considerable attention has been worldwide to promote drop wise condensation on circular tubes
using promoter like gold, silver, plasma, organic material etc., In the present work vapour deposition is used
for coating the copper tubes is proposed to use Ni-Cr and TEFLON etc., to promote the drop wise
condensation. The characteristics of drop wise condensation on various shapes of tube with three different
angle tubes were experimentally studied and their results are compared and new Correlations will be derived
for DWC for each shape of the be tube with various angles.

Published

2018-03-25

How to Cite

V.Vignesh, C.Vembaiyan, & K.Anandavelu. (2018). PERFORMANCE ANALYSIS OF DROPWISE CONDENSATION. International Journal of Advance Research in Engineering, Science & Technology, 5(3), 907–911. Retrieved from https://ijarest.org/index.php/ijarest/article/view/1391